{"id":1027913,"date":"2021-05-25T12:33:24","date_gmt":"2021-05-25T10:33:24","guid":{"rendered":"https:\/\/www.fanox.com\/in-the-beginning-all-the-protection-relays-were-self-powered\/"},"modified":"2021-05-25T12:55:50","modified_gmt":"2021-05-25T10:55:50","slug":"al-principio-todos-los-reles-de-proteccion-eran-autoalimentados","status":"publish","type":"post","link":"https:\/\/www.fanox.com\/es\/al-principio-todos-los-reles-de-proteccion-eran-autoalimentados\/","title":{"rendered":"Al principio todos los Rel\u00e9s de Protecci\u00f3n eran Autoalimentados"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>En 1924 los rel\u00e9s de protecci\u00f3n eran electromec\u00e1nicos y <strong><em><u>autoalimentado<\/u><\/em><\/strong>s. Su \u00fanica funci\u00f3n consist\u00eda en proteger (disparar un elemento seccionador en caso de cortocircuito o falta a tierra) los sistemas el\u00e9ctricos a los cuales estaban asociados.<\/p>\n<p>Con el desarrollo de la electr\u00f3nica y concretamente de los microprocesadores, en 1969 se plantean por primera vez los <strong><em>rel\u00e9s de protecci\u00f3n llamados digitales<\/em><\/strong> o num\u00e9ricos. Los nuevos rel\u00e9s adem\u00e1s de proteger realizaban funciones de monitorizaci\u00f3n, registro de sucesos, <strong><em><u>registros de oscilograf\u00eda<\/u><\/em><\/strong>, dispon\u00edan de HMI (Human Machine Interface \/ Interfaz de Hombre Maquina) con pantallas de LCD y teclado e incluso dispon\u00edan de cierta l\u00f3gica en la configuraci\u00f3n de las m\u00faltiples entradas y salidas del equipo. Este cambio de tecnolog\u00eda\/prestaciones acarreo incluso un cambio de denominaci\u00f3n, lo que antes se llamaba equipo de protecci\u00f3n ahora se llamaba equipo de protecci\u00f3n y control. Pero esta nueva generaci\u00f3n de equipos de protecci\u00f3n necesitaban <strong><em><u>alimentaci\u00f3n auxiliar<\/u><\/em><\/strong> para alimentar la electr\u00f3nica, con lo cual hubo que dotarlos de diferentes fuentes de alimentaci\u00f3n (24Vcc\/48Vcc\/110Vcc\/125Vdc\/220Vdc\/ \u2026) dependiendo de la instalaci\u00f3n, el pa\u00eds, el cliente, \u2026<\/p>\n<p>Dado que los equipos de protecci\u00f3n y control ya dispon\u00edan de microprocesadores el siguiente paso natural fue implementar comunicaciones en los equipos. Los equipos comenzaron a incorporar dos tipos de comunicaciones a trav\u00e9s de diferentes protocolos: Comunicaciones con los <strong><em>equipos de control<\/em><\/strong><em> y <\/em>Comunicaciones con el <strong><em>personal de protecci\u00f3n<\/em><\/strong><\/p>\n<p><em>Los <strong>equipos de control<\/strong><\/em> que conviven con las protecciones solicitan a estas el estado del equipo, el estado de las propias funciones de protecci\u00f3n, las medidas de corriente y tensi\u00f3n que son captadas por el equipo de protecci\u00f3n y env\u00edan \u00f3rdenes para actuar sobre los dispositivos de corte y reconexi\u00f3n gobernados por la protecci\u00f3n. Con el fin de estandarizar las comunicaciones y permitir la inter-operatividad entre equipos y fabricantes se desarrollaron diferentes normas de protocolos: DNP 3.0 (en Am\u00e9rica) y IEC60870-5-(en Europa). La estandarizaci\u00f3n del medio f\u00edsico tuvo menos<\/p>\n<p>\u00e9xito. Cada fabricante\/cliente se decant\u00f3 por un medio f\u00edsico: RS485 de par trenzado, Fibra \u00d3ptica de Cristal(FOC), Fibra \u00d3ptica de Pl\u00e1stico (FOP), diferentes buses de campo (Profibus, CAN, \u2026)<\/p>\n<p>El <strong><em>personal de protecci\u00f3n<\/em><\/strong> tambi\u00e9n quer\u00eda comunicar con los equipos de protecci\u00f3n, b\u00e1sicamente, para volcar los par\u00e1metros de protecci\u00f3n y para extraer los informes y registros. Para este tipo de comunicaciones la estandarizaci\u00f3n fue nula, cada fabricante utilizaba un protocolo, muy a menudo un protocolo propietario. El medio f\u00edsico m\u00e1s utilizado fue el RS232, con lo cual se convirti\u00f3 en un est\u00e1ndar de facto. La manera de proceder del personal de protecciones pod\u00eda ser de dos maneras: o bien se acercaban a la instalaci\u00f3n donde se encontraba el equipo de protecci\u00f3n y se conectaban localmente con un ordenador port\u00e1til o bien comunican el equipo de protecci\u00f3n a la l\u00ednea telef\u00f3nica a trav\u00e9s de un modem para luego comunicarse con la protecci\u00f3n de forma remota.<\/p>\n<p>Con la explosi\u00f3n de los sistemas de la informaci\u00f3n (internet) toman m\u00e1s importancia los equipos de comunicaci\u00f3n en los cuales el medio f\u00edsico de comunicaci\u00f3n, a trav\u00e9s de Ethernet y USB se est\u00e1 convirtiendo en est\u00e1ndares de facto. En cuanto a la estandarizaci\u00f3n de los protocolos de comunicaci\u00f3n, se hicieron esfuerzos en desarrollar normas que estandaricen y unifiquen los protocolos entre todos los equipos sean de protecci\u00f3n, de control o de comunicaci\u00f3n. La norma IEC 61850 es fruto de ese esfuerzo.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h1>No todos los rel\u00e9s de protecci\u00f3n han seguido esta evoluci\u00f3n, algunos han seguido siendo alimentados aun siendo reles digitales.<\/h1>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left wpb_content_element\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"372\" height=\"200\" src=\"https:\/\/www.fanox.com\/wp-content\/uploads\/2021\/05\/SelfpoweredRelays.Banner.jpg\" class=\"vc_single_image-img attachment-full\" alt=\"\" title=\"SelfpoweredRelays.Banner\" srcset=\"https:\/\/www.fanox.com\/wp-content\/uploads\/2021\/05\/SelfpoweredRelays.Banner.jpg 372w, https:\/\/www.fanox.com\/wp-content\/uploads\/2021\/05\/SelfpoweredRelays.Banner-150x81.jpg 150w\" sizes=\"auto, (max-width: 372px) 100vw, 372px\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Los reles autoalimentados digitales se han enfrentado a otros h\u00e1ndicaps:<\/h2>\n<ul>\n<li>Ser capaz de encenderse y estar operativo en el menor tiempo posible, hay que tener en cuenta que en ausencia de corriente en el sistema, el rel\u00e9 se encuentra apagado y tras Disparar y cortar la corriente se vuelve a apagar.<\/li>\n<li>Debe de ser capaz de funcionar con corrientes muy bajas. Si hay un defecto el\u00e9ctrico y la corriente no es suficiente como para que el rel\u00e9 este vivo, este nunca detectara el defecto.<\/li>\n<li>Para funcionar a corrientes muy bajas su consumo debe de ser muy bajo y por lo tanto su capacidad de procesado ser\u00e1 muy limitada. En consecuencia, las prestaciones que ofrecen los rel\u00e9s autoalimentados no alcanzan a los rel\u00e9s con alimentaci\u00f3n auxiliar.<\/li>\n<\/ul>\n<p><strong>Hoy en d\u00eda hay fabricantes de rel\u00e9s autoalimentados como Fanox que han conseguido implementar prestaciones de rel\u00e9s con alimentaci\u00f3n auxiliar en los rel\u00e9s autoalimentados con corrientes de arranque muy bajas y tiempos de operaci\u00f3n muy cortos:<\/strong><\/p>\n<ul>\n<li>HMI con pantalla LCD y teclado.<\/li>\n<li>Led de se\u00f1alizaci\u00f3n en memoria no vol\u00e1til.<\/li>\n<li>Comunicaci\u00f3n serie con diferentes protocolos: Modbus, DNP3 e IEC60870-5-103<\/li>\n<li>M\u00faltiples funciones de protecci\u00f3n.<\/li>\n<li>Diferentes grupos de ajustes<\/li>\n<li>Registro de informaci\u00f3n, eventos, perfil de carga e incluso registro oscilografico.<\/li>\n<\/ul>\n<p>Precisamente los registros oscilograficos es uno de nuestros \u00faltimos logros que no todos los competidores han conseguido:<\/p>\n<h2>\u00bfPor qu\u00e9 hay pocos Rel\u00e9s Autoalimentados con registros de oscilograf\u00eda?<\/h2>\n<p><strong>Los fabricantes de # SelfpoweredRelays tienen que superar dos desventajas:<\/strong><\/p>\n<p>1- Como la energ\u00eda disponible a bajas corrientes es escasa, la capacidad de procesamiento de las CPU es muy limitada, lo que dificulta enormemente la implementaci\u00f3n de registros de oscilograf\u00eda.<br \/>\n2- En un rel\u00e9 autoalimentado, el tama\u00f1o de los registros de oscilograf\u00eda es variable en funci\u00f3n del tiempo de disparo. Despu\u00e9s de un disparo, el rel\u00e9 abre el interruptor y desaparece la corriente que permite que el rel\u00e9 autoalimentado est\u00e9 vivo; por esa raz\u00f3n, es necesario cerrar el registro de oscilograf\u00eda antes de que se apague el rel\u00e9.<\/p>\n<h2>Cu\u00e1les son los pr\u00f3ximos retos que deben de superar los reles autoalimentados:<\/h2>\n<ul>\n<li><strong>Implementar funciones de protecci\u00f3n direccional: ANSI 67N y 67<\/strong><\/li>\n<li><strong>Implementar comunicaciones Ethernet con los protocolos DNP3, IEC60870-5-104 e IEC61850<\/strong><\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>En 1924 los rel\u00e9s de protecci\u00f3n eran electromec\u00e1nicos y autoalimentados. Su \u00fanica funci\u00f3n consist\u00eda en proteger (disparar un elemento seccionador en caso de cortocircuito o falta a tierra) los sistemas el\u00e9ctricos a los cuales estaban asociados.<\/p>\n","protected":false},"author":7,"featured_media":1027921,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[58],"tags":[],"class_list":["post-1027913","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-reles"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/posts\/1027913","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/comments?post=1027913"}],"version-history":[{"count":4,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/posts\/1027913\/revisions"}],"predecessor-version":[{"id":1027918,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/posts\/1027913\/revisions\/1027918"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/media\/1027921"}],"wp:attachment":[{"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/media?parent=1027913"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/categories?post=1027913"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fanox.com\/es\/wp-json\/wp\/v2\/tags?post=1027913"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}